•  DP-060-V/1-F16

Protection of power supply with output from the midle and non-grounded pole, also for powwer suply with

one pole grounded. Installation as close as possible to the protected equipment.

Technical specifications

Type of SPD

 

T3, C2

Connection (input - output) 

 

terminals-terminals

Location of SPD 

 

ST 2

Nominal voltage

Un

60V AC

Maximum operating voltage 

Uc

75V AC and 75V DC

Nominal load current 

IL

16,000A

C2 nominal discharge current (8/20 µs) per core 

In

2,00kA

C2 voltage protection level mode core-core at In

Up

390V

C2 voltage protection level mode core-PE at In 

Up

750,00V

Test voltage L+ - L- 

 

4,0kV

Test voltage L+(L-)-PE 

 

4,0kV

Test voltage M-PE 

 

4,0kV

voltage protection level L+ - L- 

 

0,39 kV

voltage protection level L+(L-)-PE

 

0,75 kV

voltage protection level M-PE 

 

0,75 kV

Maximum overcurrent protection 

 

16 A gL/gG or B 16 A

Response time L+ - L-

 

25ns

Response time L+(L-)-PE 

 

100ns

Response time M-PE 

 

100ns

Cross-section of connected conductors solid (min) 

 

0,14mm2

 

Cross-section of connected conductors solid (max) 

 

4,00 mm2

Cross-section of connected conductors stranded (min) 

 

0,14 mm2

Cross-section of connected conductors stranded (max)

 

2,50 mm2

Fault indication

 

red indicator

Degree of protection 

 

IP 20

Range of operating temperatures - min

 

-40 °C

Range of operating temperatures - max 

 

-70 °C

Mounting 

 

DIN rail 35 mm

According to standard

 

EN 61643-21+A1,A2:2013, EN IEC 61643-21+A1,A2:2012, EN 61643-11:2012, IEC 61643-11:2011

 

Write a review

Please login or register to review

DP-060-V/1-F16


Related Products

DL-Cat. 5e 16 RACK PANEL

DL-Cat. 5e 16 RACK PANEL

Fine protection for max. 24 ports of Ethernet Cat. 5. Only a shielded version is supplied. Installation at the boundary of LPZ 2 and LPZ 3 zones, dire..

Send Price Request

 Surge Arrester Varistor SPD Type O.V Max 350 VDC

 Surge Arrester Varistor SPD Type O.V Max 350 VDC

Replaceable varistor module, visual fault signaling.varistor surge arrester, designed to be installed in low, especially for secondary switchboards, t..

Send Price Request

Arrestor 3 Pole T-83 A230XF4

Arrestor 3 Pole T-83 A230XF4

Overvoltage arrester 3-pole, Dia-8x13 230 V, 10 kA / 10A  with fail safe ..

AED 3.83

FX-230 B75 T F/F

FX-230 B75 T F/F

BNC connectorsProtection for coaxial lines. Installation at the boundary of LPZ 0 and LPZ 1 zones at the line input into the building. Suitable as the..

Send Price Request