• -48V Switched 2x100A Inputs / 8x20A Outputs

The Sentry 48DCWB-08-2X100-B0NB Intelligent PDU and Remote Power Manager minimizes the impact of locked-up routers, servers and other network devices on business-critical networks. CLECs, ILECs, ISPs and enterprises use the Sentry 48DCWB-08-2X100-B0NB to manage equipment in remote sites, co-location facilities and network operation centers. Sentry 48DCWB-08-2X100-B0NB eliminates the need to dispatch a field service technician for manual intervention when devices lock-up. Using a Sentry 48DCWB-08-2X100-B0NB, the network operations center can quickly restart locked-up remote network servers to ensure that the network is fully operational around the clock.

Sentry 48 VDC PDUs provide immediate operational cost savings, including:
> Reduced field service visits 
> Improved problem/solution response time
> Improved network availability 
> Improved facility security

Eliminate the Need for a Separate Power Distribution Panel 
> The Sentry 48DCWB-08-2X100-B0NB is an intelligent unit that combines the functions of a power distribution panel and remote power management unit into a 2U 19"rack-mounted enclosure. 
> Eight output terminal connections (four per input) are rated to switch 20 amps. Each outlet is protected by interchangeable TPC fuses allowing for the current rating to be adjusted onsite.

Measurement Features 
> Use RS-232 and/or TCP/IP to monitor the status of key measurement values. Receive SNMP or email alerts as well as Syslog when a measurement value is out of a predefined threshold.

Input Feed/Outlet "On Sense" - Verifies power at each power input/outlet connection.

Load Sense - Provides an accurate, real time measurement of the current draw, in amps, for each power outlet.

Environmental Sensors - Supports two external probes that each measure temperature and humidity.




Sentry  Cabinet PDU Specifications
Item #  Inputs Rated Amperage Low Current 
High Current 
(W x H x D)
-48V Switched 2x100A Inputs / 8x20A Outputs

(2) -48VDC (-40 to -60) Input 
Terminal Blocks (+/- & G)

100A each, 200A total

None (8) 20A max outlets protected 
with TPC fuses (25A max)**
17” x 3.5” x 16”
(432 x 89 x 406mm)***
*Expansion PDU
**Available TPC Fuse Values: 10, 15, 20, 25 amp
***Dimensions exclude the 19” standard mounting brackets included with PDU
Optional Accessories
> EMTH-1-1 Combination Temperature/Humidity Probe, 10ft (3m)
> EMCU-1-1B Environmental Monitor adding
   - Two (2) EMTH-1-1 Temperature/Humidity Probes (one included)
   - One (1) EMWS-1-1 Water Sensor (sold separately)
   - Four (4) Dry Contact (NO/NC) monitoring points
   - One (1) 8-bit analog-to-digital converter (0 to 5VDC)
> SPM (Sentry Power Manager)
   - Monitor and manage multiple PDUs from a single point
   - Monitor and manage alarm conditions
   - Create reports and trends on stored data
   - Control and analyze power usage per power supply and device
   - Optional appliance or virtual version
   - VMware READY
> NEBS Level 3
> GR-1089-Core: Sections 1-4, 7, 9, and 10
> GR-63-Core: Sections 4.1, 4.2, 4.3, 4.4, 4.5, and 4.7
> ETSI EN 300 019-2-1 v2.1.2: 2000-09
> ETSI EN 300 019-2-2 v2.1.2: 1999-09
> ETSI EN 300 019-2-3 v2.2.2: 2003-04
> ETSI EN 300 132-2 V2.2.2: 2007-10
> US & Canada (cTUVus Mark) to UL 60950-1:2007 and CAN/CSA 22.2 No. 60950-1-07
> EU (TUVGS Mark) to EN 60950-1:2006 +A11
> FCC Class A, Part 15
> CE Mark
 Communications and Security
> 10/100 BaseT Ethernet
> SSLv3/TLSv1
> SNMPv2c & v3
> SSHv2
> Telnet
> RS-232 (Serial)

Remote Power Control

Individual or group outlet remote power control to cycle power and reboot any selected server(s) or other network device(s).  Use TCP/IP (HTTP, HTTPS, SSH, Telnet, SNMP) or RS-232 to communicate with each Sentry Cabinet PDU and rectify locked-up network devices. Assign outlets to a group for control of dual-power supply servers and other gear with a single command.  Create an unlimited number of groups with any combination of outlets associated to each group. Reduce Mean Time to Repair (MTTR) a failing server by controlling individual power outlet receptacles to reboot any selected server or other device.

HTTP/HTTPs Web Configuration & Control

Use the Sentry Web interface to configure each unit, including network settings, outlet naming & grouping, SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to control individual or group outlets and monitor key values, including amperage load(s), temperature/humidity and other environmental conditions. SSL security provides a secure HTTPs connection.

SNMP Management & Event Notification

The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information and control power for the individual outlets. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide remote power control. SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, closed contacts (cabinet doors open/close), as well as notification of any time an outlet status is changed (on/off).

Rack Mount Enclosure

"Horizontal" rack-mount enclosures are 17" wide and include standard mounting brackets for 19" cabinet rails.  23" brackets also available.

Secure Access - SSH or SSL Protection

Secure Shell (SSH), known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a remote device.  Sentry supports SSHv2. Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers.  Sentry supports SSLv3/TLSv1.

Firmware Flash Upgradeable

Access new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets.


The sentry family of products supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enable authentication with LDAP servers; user accounts do not need to be individually created locally on each Sentry device.
This allows administrators to pre-define and configure (in each Sentry product, and in the LDAP server) a set of necessary LDAP groups, and access rights for each. User's access rights can then be assigned or revoked simply by making the user a member of one or more pre-defined Sentry LDAP groups. User account can be added, deleted, or changed in the LDAP server without any changes on individual Sentry products.
Sentry LDAP support has been tested in the following environments:
  - Microsoft Active Directory (MSAD)
  - Novell eDirectory (eDir)
  - Open LDAP

Load Sense

Individual input current monitoring ("Load Sense") provides real-time power measurement of the load in amps on each power inlet, accessible via firmware interface.

RS-232 Control

Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.

24-Character Outlet Receptacle Names

Use the firmware interface (Web or serial) to edit individual outlet receptacles. Identify each receptacle with the device's serial number, IP address, asset allocation #, department or any other method to individually name outlets.


Write a review

Please login or register to review

-48V Switched 2x100A Inputs / 8x20A Outputs

  • AED 16,560.00

Related Products

PRO2™ Switched POPS STV-6501 20-30A/16-32A 208V/230V 3-Ph (24) C13 &(6) C19

PRO2™ Switched POPS STV-6501 20-30A/16-32A 208V/230V 3-Ph (24) C13 &(6) C19

The Server Technology® PRO2 Switched POPS CDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determ..

AED 10,630.00

PDU 4Way Left Angled Vertical Unswitched

PDU 4Way Left Angled Vertical Unswitched

XAL - Vertical Rack Mount Angled Left 16 Amps total load Supplied with 3mtrs flex to 13A UK fused plug top. Red Neon Indicated Double Pole S..

AED 223.00

PDU 6 Way Left Angled Vertical Unswitched

PDU 6 Way Left Angled Vertical Unswitched

6 WAY UK ANGLED LEFT UNSWITCHED VERTICAL RACKMOUNT PDUOperational DetailsVoltage - 230 - 250 Volts Current - 16 Amps Total Load Frequency - 50 Hz ..

AED 250.00

Adapters and Cables

Adapters and Cables

Adapters and Cables used to complete your PDU installation.  Cables and Adapters Description Part Number Serial A..

AED 55.00